F-Gas Regulation and Heat Pumps in Ireland: What Homeowners Need to Know
The EU F-gas Regulation governs the refrigerants used in heat pumps and requires that installation and servicing is carried out by certified engineers. Here is what Irish homeowners need to know about F-gas compliance and how it affects your heat pump project.
By Smart Solar Editorial · Updated 15 May 2026 · 7 min read

The EU F-gas Regulation (most recently updated as Regulation EU/2024/573) governs the use, handling, and phase-down of fluorinated greenhouse gases — commonly called F-gases — including the refrigerants used in heat pumps and air conditioning systems. For Irish homeowners, understanding the F-gas framework helps you understand why certain qualifications are needed, how refrigerant choices are evolving, and what to look for when choosing an installer.
What Are F-Gases and Why Do They Matter?
Fluorinated greenhouse gases (F-gases) are synthetic gases used as refrigerants in heat pumps, air conditioning, and refrigeration equipment. They include:
- HFCs (hydrofluorocarbons): R32 (GWP 675), R410A (GWP 2,088), R134a (GWP 1,430)
- HFOs (hydrofluoroolefins): R1234yf (GWP ~1), R1234ze (GWP ~1)
- HCFCs: Now banned in the EU
When released into the atmosphere through leaks or improper disposal, these gases contribute to climate change. Their Global Warming Potential (GWP) quantifies this — R32's GWP of 675 means 1 kg of released R32 has the same warming effect as 675 kg of CO₂.
Natural refrigerants (R290/propane, R744/CO₂, R717/ammonia) are not F-gases — they are not subject to the F-gas Regulation. This is one of the reasons the Grant Aerona⁴ R290 does not have the same regulatory future uncertainty as R32 systems.
The EU F-Gas Regulation Phase-Down
The EU F-gas Regulation (EU/2024/573) establishes a declining quota for the production and import of high-GWP HFCs into the EU, expressed in CO₂ equivalents. Key milestones:
- 2026: HFC quota at ~45% of 2009–2012 baseline
- 2030: HFC quota at ~20% of baseline
- 2050: Effectively zero for high-GWP HFCs (>150 GWP)
Practical impact for R32 heat pumps: R32 has a GWP of 675. While not being banned immediately, R32 is subject to these quota reductions. As quotas tighten, R32 prices may increase. The long-term direction is toward refrigerants with GWP below 150, or natural refrigerants entirely.
Practical impact for R290 heat pumps: R290 is a natural refrigerant (propane) with GWP of 3. It is entirely exempt from F-gas regulation quotas and phase-down schedules. For a heat pump system that will be in service for 15–20 years, this regulatory certainty is a meaningful advantage.
F-Gas Certification: Who Can Work on Heat Pumps?
Because F-gases are environmentally damaging when released, the EU requires that anyone who installs, services, maintains, or decommissions equipment containing these gases must hold an F-gas Certificate (also called an Article 10 or Section 6 certificate in different jurisdictions).
In Ireland, the Register of Contractors and Personnel (RCP) maintained by FETAC/QQI and overseen by the Environmental Protection Agency (EPA) is the authoritative body. F-gas certified engineers in Ireland typically hold:
- CITB/FETAC F-Gas Certificate at relevant category level
- Category 1: All types of equipment (required for heat pumps)
- Category 2: Specific equipment types
- Category 4: Sealed systems (applicable to some monobloc installations)
What This Means for Your Installation
Split-system heat pumps (Daikin Altherma split, Mitsubishi Ecodan, Samsung EHS split): These systems have the refrigerant circuit split between an outdoor unit and an indoor unit. The refrigerant lines are connected on-site, requiring an F-gas Category 1 certified engineer to handle the refrigerant. This is the most common type of heat pump installation in Ireland.
Monobloc heat pumps (Samsung EHS Mono HQ, Grant Aerona⁴, some Panasonic Aquarea): These systems contain all refrigerant components in the outdoor unit. Only water pipes enter the building. Installation does not require F-gas handling inside — though the engineer installing the outdoor unit should still be F-gas certified for any on-site leak testing and safety checks.
R290 heat pumps (Grant Aerona⁴): R290 is flammable (A3 classification) and requires engineers with specific R290/flammable refrigerant training. This is additional to standard F-gas certification. The pool of R290-trained engineers in Ireland is currently smaller than for R32, but growing rapidly as the market transitions.
Checking Your Installer's F-Gas Certification
Before signing a contract, ask your installer:
- "Are all engineers carrying out refrigerant work on this project F-gas Category 1 certified?"
- "Can you provide your company's F-gas registration number?"
- "Is your F-gas certification current and valid for the equipment type being installed?"
A reputable SEAI-registered installer will have no hesitation answering these questions. F-gas certification is a legal requirement — not an optional extra.
You can search the SEAI National Register for registered heat pump contractors; SEAI registration implies adherence to minimum qualification standards.
Refrigerant Handling During Installation
For a split-system heat pump (R32 or R410A), the on-site refrigerant handling involves:
Pre-charged line sets: Some manufacturers supply pre-charged refrigerant line sets that do not require field handling of refrigerant gas. These are connected with flare fittings and sealed — no refrigerant is released during connection.
Field-charged installations: The outdoor unit is installed and connected to the indoor unit with copper pipe, then the refrigerant is charged into the system using a recovery and charge cylinder. Proper leak testing (with electronic leak detector) must confirm no loss before filling.
Leak testing: All installations must be leak-tested before being put into service. Small leaks are a source of refrigerant release and are addressed immediately during commissioning.
Servicing and the F-Gas Requirement
When your heat pump needs servicing — including refrigerant top-ups, compressor replacement, or any work on the refrigerant circuit — this must be carried out by an F-gas certified engineer. Homeowners cannot legally purchase or handle HFC refrigerants.
If your heat pump loses refrigerant pressure (indicated by reduced heating output or fault codes), contact your service engineer promptly. Running a heat pump with low refrigerant charge damages the compressor and reduces efficiency.
Annual services (€80–€150) include a refrigerant pressure check, which identifies any slow leaks before they become a larger problem.
The Transition to Natural Refrigerants
The F-gas Regulation's trajectory is clear: European heat pump manufacturers are transitioning to natural refrigerants (primarily R290 and R744) as the technology for the 2025–2035 period. Daikin, Mitsubishi, Panasonic, and others have announced R290 product ranges.
For Irish homeowners choosing a heat pump in 2026:
- R32 systems are currently excellent and fully compliant — no immediate regulatory risk
- R290 systems offer future-proofing and environmental superiority
- Installer certification (F-gas or R290-specific) is mandatory for any refrigerant work
- The industry is in transition — both R32 and R290 will be common in the Irish market through to 2030
Ask your installer about their position on refrigerants and ensure they are certified for whatever refrigerant they propose to install.
Get 3 free heat pump quotes — free and no obligation.
Frequently asked questions
Does the EU F-gas regulation affect my heat pump purchase in Ireland?
Yes, indirectly. The F-gas phase-down means refrigerants like R32 (GWP 675) face quota reductions over time. This may affect long-term service costs for R32 systems. Natural refrigerant systems (R290) are exempt from F-gas restrictions and offer greater regulatory certainty.
Does my heat pump installer need to be F-gas certified?
Yes. Any engineer handling F-gas refrigerants (R32, R410A, R134a) must hold an F-gas certificate at the appropriate category. For domestic heat pump installation, Category 1 certification is required. This is a legal requirement, not optional.
Is R290 subject to F-gas regulation?
No. R290 is propane — a natural hydrocarbon refrigerant with GWP of 3. It is entirely exempt from EU F-gas quotas and phase-down regulations. However, R290 requires specific training for installers due to its flammability (A3 classification).
Will R32 heat pumps become harder to service in the future?
Potentially. As EU F-gas quotas for high-GWP HFCs are reduced, R32 may become more expensive to service (as a servicing refrigerant) from the late 2020s onwards. The extent of this depends on market dynamics and alternative supply routes. For a 15-20 year heat pump lifespan, this is a consideration.
Can I buy and top up my own heat pump refrigerant in Ireland?
No. HFC refrigerants (including R32) cannot be legally purchased or handled by uncertified persons in Ireland. Any refrigerant work must be carried out by an F-gas certified engineer. R290 (propane) is technically purchasable as a commercial gas but handling in a heat pump refrigerant circuit requires specific training.
Sources & further reading
- EU F-Gas Regulation 2024/573 — Government of Ireland
- EPA Ireland — F-Gas Regulation — Environmental Protection Agency Ireland