Heat Pumps for Irish Warehouses and Logistics Buildings
Irish warehouses and distribution centres are the largest single category of unheated or oil-heated commercial floor space. Heat pumps with destratification and radiant tube design unlock most of the savings.
By Smart Solar Editorial · Updated 18 May 2026 · 11 min read
The biggest untapped commercial heat pump opportunity in Ireland
Ireland has approximately 18 million m² of warehouse and logistics floor space (IDA, IPUT and CBRE estimates, 2024). Roughly 35% is unheated or partially heated, 40% runs on oil-fired warm air heaters, and 20% on natural gas radiant tubes. Only 5% is currently served by heat pumps.
That makes warehouses the single largest untapped commercial heat pump opportunity in the Irish market. Three factors are shifting investor attention to the segment in 2026:
- EU Taxonomy alignment requires logistics REITs and pension fund-backed sheds to demonstrate building decarbonisation
- Tenant demand from Amazon, DHL, Maersk, DSV and pharma cold-chain operators increasingly specifies heat pump heating
- Solar PV integration — Ireland's warehouse rooftop solar boom (1.2 GW installed across the segment by end-2025) makes electric heating effectively zero-marginal-cost daytime
Warehouse heating is a different design problem
The warehouse heating brief differs sharply from offices, hotels or care homes:
- Low temperature targets — typically 12–16 °C in storage areas, 18–20 °C in pick zones, only office spaces at 21 °C
- Massive air volume — typical 10–12 m clear height creates extreme stratification (10–15 °C delta floor-to-ceiling)
- Intermittent occupancy in many zones (storage seldom occupied, pick zones intermittently)
- Frequent door openings — large infiltration losses
- Single-storey, long-span structure — favours distributed rather than centralised plant
This shapes a very different heat pump architecture: low flow temperature destratification or radiant tube systems, distributed across the floor plate, rather than central LPHW plant.
Three heat pump architectures for Irish warehouses
1. Destratification fans plus low-temperature heat pump LPHW
The most common 2026 architecture for mid-sized Irish warehouses (5,000–15,000 m²):
- Air-to-water heat pump feeds W35–W45 LPHW
- LPHW distributed to floor-mounted or low-level radiator banks
- Large-diameter destratification fans mounted at 8–10 m, pushing warm air back down
- SCOP 3.6–4.0 typical because of the very low flow temperature
Capex: roughly €18–€28/m² of heated floor space. A 10,000 m² warehouse heated to 14 °C lands around €200,000–€280,000 installed.
2. Radiant tube heat pumps
For very large or tall warehouses (>15,000 m², >10 m height), radiant tube systems are increasingly specified:
- Heat pump (often R290) heats glycol or hot water to 80–90 °C
- Radiant tubes mounted at 6–8 m height
- Radiant heat warms surfaces and people directly without warming air mass
- Lower energy demand because no need to heat full air volume
Capex: roughly €25–€38/m². A 25,000 m² warehouse lands around €650,000–€950,000 installed but typically delivers 30–40% lower annual energy than destratification design.
3. Cold-chain heat pumps — heating plus chilling
Pharma, food and beverage cold-chain warehouses use ammonia (R717) or R290 heat pumps configured for simultaneous heating and chilling duty:
- Cold side chills the storage envelope to –20 to +4 °C
- Hot side provides space heating, office DHW and process water
- COP across the cycle 5.5–7.0 because both outputs are useful
This architecture is now standard on new Irish pharma warehouses (MSD Dunboyne, Pfizer Newbridge, BMS Cruiserath).
Office area within the warehouse
Most Irish warehouses include 5–15% office and amenity floor space at 20–22 °C. The economic design separates the office heating circuit (W45 LPHW or VRF) from the warehouse circuit (W35 LPHW or radiant tubes), allowing each to operate at its optimum flow temperature.
A small split VRF or air-to-water unit dedicated to the office area is typical. Trying to push a single heat pump to satisfy both office and warehouse loads on a common circuit destroys SCOP for the warehouse zone.
Solar PV pairing — the killer combination
Irish warehouse rooftops are uniquely suited to large-scale solar PV. A typical 10,000 m² warehouse can host 800 kWp–1.2 MWp of rooftop PV, generating 700–1,100 MWh/year. When paired with a heat pump heating system, the daytime PV output covers most of the heating electricity demand — especially valuable in spring and autumn shoulder seasons when both PV output and heating demand are moderate.
Real-world Irish warehouse projects in 2025 show:
- PV self-consumption of heat pump electricity: 55–70% on heating-season days
- Net heating energy cost reduction: 40–60% below grid electricity rates
- Combined PV + heat pump payback versus grid-electric resistance heating: 4–6 years
EXEED grant economics
EXEED is favourable to warehouse heating projects because the baseline is usually direct fuel (oil or gas) and the carbon delta is large. Typical EXEED grant capture:
- Oil heater replacement projects: 28–30% of eligible capex
- Gas radiant tube replacement: 22–28%
- New build with heat pump as baseline specification: 18–25% (lower baseline carbon delta)
A 10,000 m² Irish distribution warehouse replacing oil-fired warm air heaters typically captures €70k–€100k EXEED grant against €230k–€280k installed cost.
ESB Networks supply implications
Warehouse heat pump retrofit often triggers an ESB Networks upgrade conversation, particularly in older industrial estates. A 200 kW destratification heat pump system draws roughly 65–75 kW of electrical load (SCOP 3.5 design point), adding to existing forklift charging, lighting and process load.
Modern Irish warehouse parks (Northwest Logistics Park, Dublin Inland Port, Cork's Little Island) are typically specified with 800 kVA–2 MVA supplies and accommodate heat pump load without upgrade. 1990s and earlier industrial estates often require transformer upgrade.
2026 installed pricing summary
- 3,000 m² small warehouse, 80 kW system: €60,000–€90,000 installed
- 10,000 m² distribution warehouse, 200 kW destratification: €180,000–€280,000 installed
- 25,000 m² logistics shed, 500 kW radiant tube: €600,000–€950,000 installed
- 50,000 m² mega-shed, 900 kW combined: €1.0M–€1.6M installed
Practical procurement guidance
- Get a metered baseline first. Most Irish warehouses have no sub-metering on heating — install temporary meters for 60–90 days before specifying.
- Specify zoning explicitly. Office, pick zone, storage zone should each have their own circuit and setpoint.
- Specify destratification fans even with radiant tubes. Stratification recovery is the single largest efficiency lever.
- Pair with rooftop PV. Warehouse PV economics have never been better in Ireland — capture the daytime heat pump load.
- Plan installation around peak picking seasons. September–November are typically off-limits for major works in retail logistics warehouses.
Warehouses are the next major wave of Irish commercial heat pump deployment. The combination of low setpoint, distributed plant, rooftop PV synergy and strong EXEED capture makes the payback profile increasingly competitive with continued oil and gas operation, even before accounting for tenant and ESG pressure.
Get 3 free commercial heat pump quotes — free and no obligation.
Frequently asked questions
What temperature should an Irish warehouse be heated to?
Typical targets are 12–16 °C in storage areas, 18–20 °C in pick zones and 20–22 °C in office/amenity areas. Cold chain warehouses run –20 to +4 °C in storage envelopes with separate office heating. Always zone the heat pump system to match these distinct setpoints.
Is destratification or radiant tube better for a heat pump warehouse?
Destratification with LPHW radiators is the cost-leader for sheds under 15,000 m² with under 10 m clear height. Radiant tube heat pumps are better for taller, larger sheds because they avoid heating the full air volume — typically 30–40% lower annual energy at 30–40% higher capex.
Can I pair rooftop solar PV with a warehouse heat pump?
Yes, and it is the highest-ROI configuration available. A typical 10,000 m² Irish warehouse hosts 800 kWp–1.2 MWp of rooftop PV and achieves 55–70% PV self-consumption of heat pump electricity. Combined payback versus grid-electric resistance heating is 4–6 years.
How much does a warehouse heat pump cost in Ireland?
Indicative 2026 installed pricing: €60k–€90k for 3,000 m² (80 kW), €180k–€280k for 10,000 m² (200 kW destratification), €600k–€950k for 25,000 m² (500 kW radiant tube). EXEED typically captures 25–30% of eligible capex on oil-replacement projects.
Sources & further reading
- EXEED Certified Grant — SEAI
- EU Taxonomy for Sustainable Activities — European Commission
- ASHRAE Handbook - Industrial Ventilation — ASHRAE